C3 Series Quick Specs
C300
C310
C320
C330
Telescope
Image Erect Erect Erect Erect
Magnification 28x 26x 24x 22x
Field of View 1º25'
(2.5ft. @100 ft.)
1º25'
(2.5ft. @100 ft.)
1º25'
(2.5ft. @100 ft.)
1º25'
(2.5ft. @100 ft.)
Minimum Focus 1 ft. 1 ft. 1 ft. 1 ft.
Stadia Ratio 1:100 1:100 1:100 1:100
Leveling Accuracy (all models)—in 1 mile / 1.0 km of double-run leveling
Standard Deviation ±0.008 ft. / 2.0mm ±0.008 ft. / 2.0mm ±0.008 ft. / 2.0mm ±0.008 ft. / 2.0mm
Compensator
Setting Accuracy 0.5" 0.5" 0.5" 0.5"
Range ±15' ±15' ±15' ±15'
Level Vial (all models)—circular
Sensitivity 10' / 2mm 10' / 2mm 10' / 2mm 10' / 2mm
C3 Series - Technical Tips
Automatic levels are affordable and easy to use, but they still are precision instruments. One of the most useful tools for the user in the field is to know how to check their level by performing a “Peg Test”. This test checks the line of sight and confirms that the level is reading true.

1) Set the instrument at a point halfway between points A and B. Take readings a1 and b1. 

2) Set the instrument at a point 2m from point A. Take readings a2 and b2.
3) Calculate
b2= a2 - (a1 - b2) If b2 = b2 , the horizontal cross- line is normal and no adjustment is necessary.

If the instrument does not read true, consult the manual for instructions on adjusting the instrument.

Brochures are available in PDF format where you see this symbol:

To download Adobe Acrobat Reader, click here: 

 


Copyright © 1997-2003. Instrument Sales.

Copyright ©2000-2002 Instrument Sales No part of this page may be reproduced without the express written permission of Instrument Sales.
All orders are encrypted. We will never sell or give your information to any other company without your permission.

All brand names and trademarks are property of their respective owners.

Prices and specifications are subject to change without notice.